Home of the World's Leading

Static Protective FIBC Fabric

      CROHMIQ®, There Is No Substitute, We Keep You Safe         

FIBC - Color Blue Registered Trademark for Bulk Bags The Color Blue is a Registered Trademark of TEXENE LLC - More.....
CROHMIQ is protected by US Patents 5,478, 154; 5,679,449; and 6,112,772
Additional International Patents and Patent Pending

THE CROHMIQ SAFETY ADVANTAGE

  

 

PROVEN BY INDEPENDENT TESTING

  • CROHMIQ Type D FIBC Electrostatic Ignition Test Reports from Chilworth & Swiss InstituteChilworth Technology, Inc.
  • Swiss Institute for Safety & Security
  • Dr L G Britton

  
15 YEAR SAFETY RECORD

  • CROHMIQ is the world's safest static protective Flexible Intermediate Bulk Container (FIBC) fabric that does not require grounding
  • Proven safety with over 15 million CROHMIQ Type D FIBC used since 1995 without incident in multiple products, industries, & combustible environments
  • Over 40 billion pounds of products such as chemicals, foods, and pharmaceuticals have been safely packaged in CROHMIQ FIBC
  • Leading global companies don't compromise safety because they use CROHMIQ blue® bulk bags to protect their personnel and customers from the dangers of electrostatic discharges
  • Leading companies recognize the blue color fabric used on FIBC as a TEXENE quality product
  • When safety matters, depend on CROHMIQ and do not allow substitutions as CROHMIQ is the world's premier static protective FIBC fabric

SAFE TECHNOLOGY

  • CROHMIQ is the leading Type D technology for electrostatic protective FIBC 
  • Safely dissipates static charge without the need for a ground/earth connection
  • CROHMIQ big bags can be safely used earthed or unearthed, whereas Type C FIBC must be earthed securely and correctly in order to dissipate electrostatic charges

HYGIENIC

  • Complies with Federal Food, Drug, and Cosmetic Act (FDA) and European Union (EU) regulations for use in the storage and transportation of dry goods
  • CROHMIQ static control bulk bags are safe to store and transport food products and pharmaceuticals

FREEDOM

  • Freedom from cumbersome grounding systems required when using Type C totes
  • Freedom from the risk of human error

VERSATILITY

  • No special FIBC design requirements in the manufacturing process
  • Coated or uncoated antistatic FIBC fabric
  • Plain or antistatic, attached inner liners may be used

RELIABILITY

  • Static protective properties are inherent to CROHMIQ Type D bulk bags
  • No degradation with time, usage, refurbishment, or washing
  • Over 3 million CROHMIQ FIBC safely reused after wet or dry-process refurbishment

THE LEGITIMATE TYPE D FIBC FABRIC

  • The world's first effective, and still leading technology, static protective bulk bag fabric that does not require grounding

ON-SITE ELECTROSTATIC TEST LABORATORY

  • World-class electrostatic ignition FIBC-test laboratory at company headquarters in South Carolina, USA
  • Facilities for electrostatic ignition tests on FIBC, breakdown voltage tests on fabric, and a range of other electrostatic tests
  • Regularly used by the world's leading electrostatic experts
  • Random testing of production goods ensures safe, reliable electrostatic protective FIBC performance

PRODUCT SUPPORT

  • Global network of Texene Qualified Suppliers
  • Electrostatic experts on staff
  • Global technical support available online, telephone, or locally on-site
  • Representation on National & International Standards Organizations

COMPLIES WITH INTERNATIONAL ELECTROTECHNICAL COMMISSION STANDARD: IEC 61340-4-4: 2005

  • Meets the requirements of Clause 5.2 for breakdown voltage on FIBC fabrics
  • Meets the requirements of Clause 5.3 for ignition testing on FIBC

COMPLIES WITH CENELEC TECHNICAL REPORT: CLC/TR 50404: 2003

  • Meets the safe FIBC performance requirements of Clause 7.2.6.8.4 - "no incendive discharges will occur"

COMPLIES WITH NATIONAL FIRE PROTECTION ASSOCIATION STANDARD: NFPA 654: 2006

  • Complies with Clauses 9.3.3.1.(4) for safety requirements for Ungrounded/Type D FIBC
  • Complies with Clause 9.3.3.2 for FIBC that have been listed or tested by a recognized testing organization

ABOUT STATIC PROTECTIVE FIBC FABRICS

As the use of Flexible Intermediate Bulk Containers (FIBC/bulk bags/totes/super-sacks/big bags/IBC) increases globally, safely managing the occurrence of static electricity during FIBC filling and emptying operations is a critical concern for many industries.  Industries susceptible to electrostatic hazards include chemicals, foods, pharmaceuticals, and minerals. Since FIBC are made from polypropylene, a highly insulating material, they are prone to building up static electricity as friction and separation occur during filling and discharging of the products within the bulk bag.  Static discharges from bulk bags can range in severity from operator nuisance shocks to those capable of igniting flammable gases, vapors and dusts. By using FIBC with static protective properties, also known as antistatic FIBC, antistatic bulk bags, or electrostatic FIBC, the risk of a hazardous static discharge is significantly reduced.

FIBC made of CROHMIQ® static protective FIBC fabric are static dissipative Type D FIBC. Using CROHMIQ fabric to construct anti-static big bags eliminates the inherent risk of grounding failure that is always present whenever conductive Type C FIBC (grounded FIBC) are used. For these reasons, over the past 15 years, leading companies have been switching away from the risks of grounded FIBC (Type C) to the proven safety of CROHMIQ Type D big bags. For these reasons, the use of Type C super-sacks is less and less each year as a result of the conversion to CROHMIQ brand Type D FIBC.

There are very important differences between Type D FIBC and Type C FIBC, specifically on the mechanism of safety from electrostatic discharges and proper use.  Firstly, Type C totes are groundable bulk bag packaging and must be properly and firmly grounded to be safe, whereas CROHMIQ Type D FIBC do not need to be grounded to be safe. While CROHMIQ Type D bulk bags can also be grounded, there is no need to do so as CROHMIQ Type D FIBC are already safe when used ungrounded.

Type D bulk bags are sometimes called antistatic FIBC or totes, groundable D or Type D+ FIBC / Type D plus bulk bag, or Type C/D FIBC. However, only CROHMIQ is the leading static protective FIBC fabric because CROHMIQ Type D FIBC are inherently antistatic and do not require grounding to be safe.  Products marketed as Type D+ FIBC, groundable Type D FIBC or Type D plus bulk bags generally must be grounded to be close to safe, thus defeating the purpose of using a genuine, ungrounded, safe CROHMIQ Type D FIBC. 

Thus, as a result of CROHMIQ's perfect safety record, leading chemical companies around the world, trust and insist on CROHMIQ bulk bags as their only static protective FIBC packaging solution. As the leading antistatic FIBC product in the market, CROHMIQ's state of the art technology outperforms inferior imitations. This is why when safety matters, Fortune 500 companies trust and use CROHMIQ. Process safety experts in the field of electrostatics and static hazards have written articles about performance and test standards and the improved safety of Type D super-sacks compared to other types of super-sacks. CROHMIQ's design engineers invented and patented the first fabric and still leading technology for Type D FIBC.   

TEXENE, the company behind CROHMIQ, continues to perform research and development on Type D antistatic FIBC and electrostatic phenomena in FIBC. Texene is recognized for its high quality fabrics used to make bulk containers for industrial use. The technology in CROHMIQ fabrics is protected by several patents around the world. Additionally, Texene's goodwill is symbolized by the trademarks used in connection with its products. For this reason, Texene obtained United States trademark registration No. 3,097,115 for the "COLOR BLUE" mark covering "synthetic resinous fabrics for use in the manufacture of bulk containers in the nature of bags and wraps for industrial use." Texene uses the color blue in the manufacture of its CROHMIQ FIBC fabrics, thus no unauthorized use of its color blue mark is allowed for NON-CROHMIQ FIBC products.

TEXENE LLC, Textile Technologies of the 21st Century
Textile Technologies of the 21st Century


TEXENE LLC is a leading manufacturer of technical textiles focused on delivering precision engineered, safety performance products worldwide.

ARTICLES ON ELECTROSTATICS

STATIC HAZARDS USING FLEXIBLE INTERMEDIATE BULK CONTAINERS FOR POWDER HANDLING
In the early 1990's, Dr Laurence G. Britton, a highly respected process safety engineer with Union Carbide Corp. (later Dow Corp.), conducted a study of fire and explosion incidents that occurred when FIBC were ...

DANGERS OF COMBUSTIBLE DUST EXPLOSIONS, OSHA REGULATIONS, AND ANTISTATIC FIBC
Following three fatal dust explosions in 2003 alone, the US Chemical Safety & Hazard Investigation Board (CSB) launched a wide ranging study of industrial dust explosions.  This first issue of our Electrostatic Safety ...

CHOOSING SAFE STATIC CONTROL FIBC
The second issue of our Electrostatic Safety Review outlines the development of conductive Type C FIBC and the later development of CROHMIQ, the world's first truly effective Type D FIBC fabric, which provides ...

TESTING & CERTIFYING THE SAFETY OF STATIC PROTECTIVE FIBC
The third issue in our series of Electrostatic Safety Reviews describes the rigorous testing that is demanded by national and international standards such (IEC, CENELEC, NFPA, etc.) in order to prove the safety of ...

NEW DEVELOPMENTS IN SAFETY STANDARDS FOR STATIC PROTECTIVE FIBC
Companies that handle combustible powders in bulk bags, or empty products from bulk bags in environments where flammable solvents may be present rely on safe antistatic FIBC to prevent fires and explosions. Proving safety ...

CHEMICAL ACCIDENTS IN THE NEWS

Sep 8th, 2010
DuPont leak closes Ohio park
NORTH BEND, Ohio (AP) — Fire officials say a gas leak at a DuPont plant just ...

Sep 8th, 2010
ULM Chemistry and Science Building evacuated Wed. morning
MONROE, La. (KNOE 8 News)--Students at the University of Louisiana at Monroe were evacuated Wednesday ...

Sep 7th, 2010
Fire in Chemistry-Physics Building
A chemical fire occurred in the Chemistry-Physics Building Tuesday afternoon. The Lexington Fire Department initially ...

Sep 7th, 2010
Fire breaks out at Lawrenceville recycling center
A fire at a Lawrenceville recycling center Tuesday afternoon was contained quickly and emergency personnel ...

Sep 7th, 2010
UPDATE: Chemical Fire at Pollution Control Company Near Millington
| MEMPHIS, TN – Shelby County firefighters battled a chemical fire inside Pollution Control Industries in North ...

Sep 5th, 2010
Fire damages Maidencreek recycling business
Firefighters from several Berks County companies responded to a report of a fire at the ...

Sep 4th, 2010
Explosion damages gatehouse at Mohonk Mountain House
NEW PALTZ — A propane explosion early Saturday caused significant damage to the gatehouse at the ...

Sep 4th, 2010
Propane exploision in Collingdale led to evacuations
View and purchase photos Fire at Scully's, a propane facility in Collingdale led to evacuations ...

Sep 3rd, 2010
Platform fire expands worry on oil drilling
Shallow-water accident raises wider... ...

Sep 2nd, 2010
Oil Spill Seen In Gulf Platform Explosion
An oil and gas platform in the Gulf of Mexico exploded on Thursday, setting off ...

Sep 1st, 2010
Residents displaced by propane leak allowed to move back home
GILBOA, N.Y. -- The remaining residents displaced by last week's propane leak in Gilboa ...

Aug 31st, 2010
Chlorine leak contained at central Iowa General Mills plant
Officials are looking for the source of a small chlorine leak at a General Mills ...

Aug 31st, 2010
Explosion at BSU scares students, injures worker
BOISE -- It was quite the scare on the Boise State campus Monday as a ...

Aug 30th, 2010
Gas leak forces evacuations in Calhoun
Atlanta Gas Company works to repair the 2" gas line that was busted in downtown Calhoun. (...

Aug 30th, 2010
MUST SEE: Hydrogen fuel explosion caught on tape
ROCHESTER, NY (CNN) - Newly released surveillance video may help investigators figure out what caused ...

Aug 30th, 2010
Evacuation order cancelled for chemical leak
People, evacuated from their homes after a chemical in North Baton Rouge, are now allowed ...

Aug 30th, 2010
Ammonia leak reported at Georgia poultry plant
ROCKMART, Ga. -- Authorities say an ammonia leak at a West Georgia poultry plant sent 23 ...

Aug 30th, 2010
Tesoro: Hydrogen Attack Caused Anacortes Blast
Tesoro Anacortes Refinery announced Friday what investigators determined was the likely cause of an April 2 ...

Aug 30th, 2010
Blaze Erupts At Scrap Yard In Aliquippa
ALIQUIPPA, Pa. -- Firefighters spent early Monday morning battling a blaze that broke out at ...

Aug 29th, 2010
Long Island Man Burned In Garage Explosion
BY ADRIAN CARRASQUILLO A Baldwin man and his son were working in their detached garage ...

Aug 29th, 2010
BRIDGEPORT BLAZE: Fire hits abandoned ammunition plant
Click to enlarge Firefighters with Ladder 11 battle a fire at the former Remington Arms plant, ...

Aug 29th, 2010
Chemical Spill Sickens Dozens in Vegas
CNN that a chemical spill in the pool area of the MGM Grand Hotel in ...

Aug 27th, 2010
Eleven Treated At Possible SF Wharf Hazmat Site
SAN FRANCISCO -- A possible hazardous materials incident at a recycling facility at Pier 96 in ...

Aug 27th, 2010
Pinhole leak reported at Valero hydrocracker in Benicia
BENICIA -- Valero Energy Corp. this week reported yet another vapor release at its Benicia ...

Aug 27th, 2010
Explosion near Rochester airport deemed an accident
A fiery explosion that shook the Greater Rochester International Airport and was heard across the ...

Aug 25th, 2010
1 injured in gas compressor station explosion
at 4:18 p.m. Last Modified: Wednesday, August 25, 2010 at 4:18 p.m. SHONGALOO, La. - An explosion ...

Aug 25th, 2010
Rockmart poultry plant leak caused by faulty seal; More than 20 sent to hospitals
Floyd Medical Center employee Katie Hastey helps a Rome Fire fighter change into protective gear ...

Aug 24th, 2010
Fire does minor damage at S.D. ethanol plant
CHANCELLOR (AP) — A spokesman for Sioux Falls-based ethanol producer Poet says a fire at a ...

Aug 24th, 2010
At least 120 sent to hospitals by ammonia leak at Ala. plant; 4 in intensive care
THEODORE, ALA. — An ammonia leak at a coastal Alabama chicken distribution plant sent more than 120 ...

Aug 23rd, 2010
Weekend ammonia leak at Cutler packing plant sent six to hospital; repairs must be made before business can reopen
Six workers at the Wawona Packing plant in Cutler suffered what are believed to be ...